Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Intervalo de año de publicación
1.
Biomimetics (Basel) ; 9(2)2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38392119

RESUMEN

Implementing in silico corneal biomechanical models for surgery applications can be boosted by developing patient-specific finite element models adapted to clinical requirements and optimized to reduce computational times. This research proposes a novel corneal multizone-based finite element model with octants and circumferential zones of clinical interest for material definition. The proposed model was applied to four patient-specific physiological geometries of keratoconus-affected corneas. Free-stress geometries were calculated by two iterative methods, the displacements and prestress methods, and the influence of two boundary conditions: embedded and pivoting. The results showed that the displacements, stress and strain fields differed for the stress-free geometry but were similar and strongly depended on the boundary conditions for the estimated physiological geometry when considering both iterative methods. The comparison between the embedded and pivoting boundary conditions showed bigger differences in the posterior limbus zone, which remained closer in the central zone. The computational calculation times for the stress-free geometries were evaluated. The results revealed that the computational time was prolonged with disease severity, and the displacements method was faster in all the analyzed cases. Computational times can be reduced with multicore parallel calculation, which offers the possibility of applying patient-specific finite element models in clinical applications.

2.
Comput Biol Med ; 170: 107870, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38217971

RESUMEN

A biomechanical model that simulates the physiological pressure load on the cornea without considering the stresses in vivo will result in an overstress or underestimation of the stress field and incorrect deformation of the corneal structure. Therefore, it is essential to propose numerical models that consider the stress-free geometry of the cornea. In this study, the Displacement and Pre-stress methods were compared to obtain the stress-free geometry (S-FG) and the physiological estimated geometry (P-EG), based on the patient-specific geometric behavior and the computational time required to reach each geometry. The same shape and contour conditions were considered in the models obtained from both methods for each of the pathological scenarios analyzed. Both methods behaved differently to obtain the free geometry, and this difference increased with the severity grade of the disease. However, they behaved in a similar way to reach the physiological estimated geometry. The Displacement method required a lower computational cost to reach the free geometry, with both methods presenting a similar computational cost to obtain the physiological geometry. The stress-free geometries obtained by both methods allowed to characterize the existing biomechanical decompensation during the progression of the diseases. In conclusion, the calculation of the stress-free corneal geometry associated to the clinically measured intraocular pressure with the Displacement and Prestress Methods in keratoconus eyes allows the development of accurate and useable models in clinical practice in real time. This displacement method shows some benefits in terms of computational cost.


Asunto(s)
Queratocono , Humanos , Fenómenos Biomecánicos , Córnea , Tonometría Ocular , Presión Intraocular
3.
Polymers (Basel) ; 13(12)2021 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-34201083

RESUMEN

The use of composite materials has shown steady growth in recent years due to their excellent specific mechanical properties and the possibility to reduce the weight of vehicles without impairing their safety and comfort. Continuous fibre-reinforced thermoplastic composites (CFRTP) show dynamic, acoustic, and damping properties far superior to steel and can be recycled and repaired. Their excellent properties make CFRTP good candidates for anti-vibration and shock absorbing components, however, out-of-plane mechanical properties hinder the anchoring to the vehicle's body by means of bolted connections. The results obtained in this study show how the maximum torque that can be applied without cracks or breakage phenomena is lower than in standard steel joints. Although the preload's value is admissible, this one is reduced over time due to relaxation phenomena associated with the viscoelastic behaviour of thermoplastic matrix. The results obtained can be improved with the integration of metal inserts in connections' areas. In this study, a case study of a gear mount replacing the steel core with CFRTP reinforced with inserts is carried out. The results show a reduction above 50% in weight, opening the possibility of lighter structures in the automotive sector.

4.
Materials (Basel) ; 14(3)2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33498487

RESUMEN

The aim of this work was to show the evolution over time of the dynamic moduli in components made of Polybutylene Terephthalate reinforced with glass fiber when they are held to temperatures close to the glass transition temperature over time. For this purpose, PBT samples reinforced with short, glass fibers of Ultradur® material with 0%, 20%, and 50% in weight content were tested. Dynamic moduli showed an increment with glass fiber content showing a nonlinear behavior with the temperature. The evolution of storage modulus was depicted by means of a modified law of mixtures with an effectiveness factor depending on temperature and fiber content, whereas the evolution over time was obtained with a time-temperature transformation generated with the TTS Data Analysis software of TA-instruments for a given temperature. Storage modulus showed a linear relationship with glass fiber content when components were held to temperatures near to their respective glass transition temperature, obtained from the maximum of loss modulus curve with temperature. In summary, the value and evolution of dynamic moduli of PBT samples improved with glass fiber content, allowing us to increase the durability of components when they are submitted to high-temperature environments.

5.
Ecohealth ; 16(2): 210-221, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31114946

RESUMEN

The global expansion and proliferation of Aedes aegypti and Aedes albopictus represents a growing public health threat due to their capacity to transmit a variety of arboviruses to humans, including dengue, chikungunya, and Zika. Particularly important in urban regions, where these species have evolved to breed in man-made containers and feed nearly exclusively on human hosts, the threat of vector-borne disease has risen in recent decades due to the growth of cities, progression of climate change, and increase in globalization. While the dynamics of Aedes populations in urban settings have been well studied in relation to ecological features of the landscape, relatively less is known about the relationship between neighborhood socioeconomic status and Aedes infestation. Here, we compare infestation levels of both A. aegypti and A. albopictus in four socioeconomically contrasting neighborhoods of urban Panama City, Panama. Our results indicate that infestation levels for both Aedes species vary between neighborhoods of contrasting socioeconomic status, being higher in neighborhoods having lower percentage of residents with bachelor degrees and lower monthly household income. Additionally, we find that proximity between socioeconomically contrasting neighborhoods can predict infestation levels by species, with A. aegypti increasing and A. albopictus decreasing with proximity between neighborhoods. These findings hold key implications for the control and prevention of dengue, chikungunya, and Zika in Panama, a region with ongoing arbovirus outbreaks and high economic inequity.


Asunto(s)
Aedes , Características de la Residencia/estadística & datos numéricos , Animales , Ciudades/estadística & datos numéricos , Humanos , Panamá/epidemiología , Densidad de Población , Dinámica Poblacional , Factores Socioeconómicos
7.
Curr Drug Saf ; 2013 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-23909707

RESUMEN

Levofloxacin induced psychiatric adverse effects are rare, although they can be serious. There are just five cases of fluoroquinolone-induced delirium published in the medical literature. To our best knowledge, none of them occurred in psychotic patients. We report a case of a 38-year-old Caucasian man diagnosed with schizoaffective disorder and multiple sclerosis who developed delirium and visual hallucinations after initiating levofloxacin therapy. In psychiatric patients, suspecting levofloxacin could be responsible for the symptoms can be a diagnostic challenge, since they could be interpreted like worsening of the mental state as well. Although levofloxacin-induced delirium is a rare adverse event, physicians should be aware of the occurrence of this serious, but potentially reversible CNS complication of levofloxacin, even in psychotic patients.

8.
Curr Drug Saf ; 8(3): 199-200, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23914753

RESUMEN

Levofloxacin induced psychiatric adverse effects are rare, although they can be serious. There are just five cases of fluoroquinolone-induced delirium published in the medical literature. To our best knowledge, none of them occurred in psychotic patients. We report a case of a 38-year-old Caucasian man diagnosed with schizoaffective disorder and multiple sclerosis who developed delirium and visual hallucinations after initiating levofloxacin therapy. In psychiatric patients, suspecting levofloxacin could be responsible for the symptoms can be a diagnostic challenge, since they could be interpreted like worsening of the mental state as well. Although levofloxacin-induced delirium is a rare adverse event, physicians should be aware of the occurrence of this serious, but potentially reversible CNS complication of levofloxacin, even in psychotic patients.


Asunto(s)
Antibacterianos/efectos adversos , Delirio/inducido químicamente , Levofloxacino/efectos adversos , Trastornos Psicóticos/complicaciones , Adulto , Antibacterianos/uso terapéutico , Alucinaciones/inducido químicamente , Humanos , Levofloxacino/uso terapéutico , Masculino , Esclerosis Múltiple/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...